EMC
LED Power Supplies
35W
Parameter
Standard
Level
Units
Emissions
Conducted
Radiated
Harmonic Distortion
Flicker and Fluctuation
Immunity
ESD
Radiated RFI
Fast Transients - burst
Conducted RFI
Power Freq Magnetic Field
Voltage Dips
Dimming Control
EN55015
EN55015
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-8
EN61000-4-11
Level B
Level B
Compliant
Compliant
Level 4
Level 3
Level 4
Compliant
Compliant
Compliant
Parameter
10V Output Voltage
10V Output Source Current
Min
9.8
-10
Nom
10.0
Max
10.2
2
Units
VDC
mA
Control Voltage (1-10V input
Voltage applied on 1-10V input wire
-2
15
V
Source Current (1-10V input) Source current on 1-10V input wire
0
1
mA
Note
Note
Note
Note
Note
Note
Note
Note
A.
B.
C.
D.
E.
F.
G.
H.
If dimming function is not used, 10V(yellow) and 1-10V(purple)wire must be connected together.
Primary to Secondary Isolation test not to be carried out on power supply.
Load Voltage must be maintained above minimum voltage. See models for voltage range.
Dimming range is 20%-100%
Dimming Signal Voltage should be above 1V for linear dimming control.
See Dimming Implementation diagrams for various dimming methods.
Do not connect GND of Dimming cable to Output..
UL1310 Class 2 outputs for US and Canada except LXD35-0700SW which is Class 2 in US only
INPUT / OUTPUT WIRING
INPUT CABLE
SJTW 18AWG 3C
Black (L),White(N), Green (G)310±20mm
MECHANICAL SPECIFICATIONS
OUTPUT CABLE
SJTW 18AWG 2C
Black (-V) and Red (+V) 300±20mm
DIMMING CABLE
SJTW 22AWG 3C
Yellow (10V), Purple (0-10V), Green (GND)
193
172
168
270 ± 20
50±5
10±2
10±2
10±2
50±5
310 ± 20
300 ± 20
50±5
34.5
2
183 ± 0.5
8
2 x 5.5dia
5
8
8
5
8
Specifications are subject to change without notice
Europe/Asia
North America
Excelsys Technologies Ltd
27 Eastgate Drive
t: +353 21 4354716
f: +353 21 4354864
Excelsys Technologies
519 Interstate 30, #309
t: (972) 771 4544
f: (972) 421 1805
Eastgate Business Park
Little Island, Cork, Ireland
IRELAND
e: sales@excelsys.com Rockwall, TX 75087
USA
e: salesusa@excelsys.com